AudioCodes SBA – Lync CMS Replica Issue

July 30, 2011 Leave a Comment

I recently experienced an issue when configuring an AudioCodes Mediant 1000 MSBG Survivable Branch Appliance for Lync Server 2010. When working through the SBA configuration wizard and getting to the “Backup Replica” stage, this would consistently fail with the following error:

cannot open database xds requested by the login. The login failed. Login failed for user ‘Domain\SBACOMPUTERNAME’

After performing some research on this issue and attempting fixes detailed in other blogs in regards to ensuring the RTCUniversalSBATechnicians Active Directory group was added to the local administrators group on the SBA, I was not having much joy. To work around the problem and get a replica of the CMS database onto the SBA, in order to proceed with the installation, the following was performed.

1. Connect to the server that hold the front end role in your Lync Server 2010 environment.

2. Open the Lync Management Shell and type the following command: Export-CsConfiguration -FileName “C:\Config.zip”

3. Once the command has completed, navigate to the C:\ of the front end server and then copy the generated “Config.zip” file to the root of the SBA’s C:\ drive. This can be acheieved by browsing to the C$ share of the SBA.

4. Once the Config.zip file has been copied to the SBA, make and RDP connection to the appliance and open the Lync Management Shell.

5. Once the Lync Management Shell has loaded, enter the following command: Import-CSConfiguration -Verbose -LocalStore -FileName ‘C:\config.zip”

6. Once the command has completed, a replica of the CMS will have been imported into the SBA. You can confirm if this was successful by opening the Lync Control Panel on your front end server, selecting the topology tab and confirming the SBA object has a green check next to replication. You can now complete the remainder of the SBA setup.

That’s it, the SBA should now work as intended and replicate correctly with the CMS.

OCS AudioCodes, cannot open database xds requested by the login. The login failed., CMS, CsConfiguration, Lync Server 2010, Mediant 1000 MSBG, SBA, SBA CMS Replication, Survivable Branch Applicance

Search Content

Blog Archive

  • August 2015
  • January 2015
  • November 2014
  • September 2014
  • May 2014
  • April 2014
  • March 2014
  • December 2013
  • September 2013
  • July 2013
  • March 2013
  • February 2013
  • September 2012
  • June 2012
  • May 2012
  • April 2012
  • February 2012
  • January 2012
  • November 2011
  • July 2011
  • June 2011
  • May 2011
  • April 2011
  • March 2011
  • February 2011
  • January 2011
  • December 2010
  • November 2010
  • October 2010
  • September 2010
  • August 2010
  • July 2010
  • June 2010
  • May 2010
  • April 2010

Meta

  • Log in
  • Entries feed
  • Comments feed
  • WordPress.org
© 2022 B4Z.co.uk. All rights reserved.
Fashionista by aThemes